808 Laser Power Supply [Medical Aesthetics Engine]

Microsecond - level Precise Energy Control, Ensuring Both Efficacy and Safety

► Sufficient energy: The output voltage ranges from 12 - 40V, the output current ranges from 50 - 200A, the maximum output frequency is 80Hz, and the maximum output pulse width is 40%.
► Precise and controllable: The current accuracy is less than ±1%, and the pulse width accuracy is ≤±1%, ensuring that every energy output is precisely controllable.
► High integration: Equipped with our company's dedicated whole - machine control system, covering all functions such as detection, control, refrigeration, laser drive, and human - machine interaction.
► High safety: Built - in intelligent control limits the maximum energy output (current, pulse width), ensuring the safety and reliability of the laser and extending its service life.


  Связаться сейчас
информация о продукте
Boost the High - Performance Leap of Laser/Medical Aesthetics Equipment!
Introduction (Addressing Pain Points)
In the field of medical aesthetics, are you often troubled by these problems?
❌ Unstable energy of medical aesthetics equipment (such as 808 hair removal devices) affects treatment efficacy, resulting in low customer recognition.
❌ Low integration level means that a large number of accessories are required for the production of the whole machine. This not only consumes time and labor in production, increases labor costs, but also makes the equipment more prone to problems.
❌ Poor compatibility leads to a long development cycle.
❌ Insufficient power supply power cannot fully exert the energy efficiency of the laser. Moreover, long - term use may cause the beauty instrument to shut down automatically.
❌ Inadequate internal protection measures of the power supply are likely to damage the laser.
In high - end medical aesthetics projects such as photon rejuvenation and laser hair removal, every "energy release" of the equipment is related to the safety and treatment effect of users.
808 Laser Power Supply - The "Powerful Heart" of Medical Aesthetics Equipment

With medical - grade precise control and ultimate stability, it enables risk - free operation of the instrument, achieving a win - win situation for treatment efficacy and reputation!

1.jpg

[Here should be the corresponding image with captions: 808 Laser Power Supply, BG NL, Yout-, Yout+, Medical - grade Precise Control, Ultimate Stability]
Core Advantages (Deeply Integrated with Medical Aesthetics Scenarios)
  1. Microsecond - level Precise Energy Control, Ensuring Both Efficacy and Safety

► Sufficient energy: The output voltage ranges from 12 - 40V, the output current ranges from 50 - 200A, the maximum output frequency is 80Hz, and the maximum output pulse width is 40%.
► Precise and controllable: The current accuracy is less than ±1%, and the pulse width accuracy is ≤±1%, ensuring that every energy output is precisely controllable.
► High integration: Equipped with our company's dedicated whole - machine control system, covering all functions such as detection, control, refrigeration, laser drive, and human - machine interaction.

► High safety: Built - in intelligent control limits the maximum energy output (current, pulse width), ensuring the safety and reliability of the laser and extending its service life.

2.jpg

[Here should be the corresponding image with captions: Microsecond - level Precise Energy Control, Ensuring Both Efficacy and Safety, Long - pulse Output Mode, Limiting the Maximum Output Pulse Width]
  1. Easy and Flexible Adaptability, All - Day High - Efficiency Operation

► Three control methods are available: LCD screen control, external analog control, and host computer control. This meets the operation requirements in different scenarios and realizes more efficient and flexible treatment management.

► Multiple alarm and protection mechanisms: When overloading, overheating, or over - current occurs, the alarm mechanism is activated. This improves safety, extends the service life of the equipment, reduces the equipment failure rate, and ensures that the equipment can operate continuously at a high intensity for 24 hours without frequency reduction.

3.jpg

[Here should be the corresponding image with captions: Operation Interface, Easy and Flexible Adaptability, All - Day High - Efficiency Operation, 808 Operation Interface, Multiple Alarm and Protection Mechanisms for Overloading, Overheating, and Over - Current, Three Control Methods: LCD Screen Control, External Analog Control, and Host Computer Control]
  1. Minimalist Medical Aesthetics, Compact Design

► Compact size: With a modular structure, the volume is reduced by 35%, and it supports rack - mounted/embedded installation.

► Black - and - white matte shell: It is fingerprint - resistant and corrosion - resistant, and is suitable for the simple beauty decoration style.

4.jpg

[Here should be the corresponding image: tmp/52324189442_docx.datword_media_image4.jpeg]
Comparative Advantages vs. Competitors
Function
Ordinary Competitive Power Supplies
RaySource 808 Power Supply Solution
Energy Stability
±2%
≤±1.5%
Basic Protection
Over - current, Over - voltage
6 - fold protection including over - load, over - current, over - voltage, etc.
Power Limitation Protection
None
Internal output power limitation function to protect the laser from damage
Size
Too large
Compact size: 29415176mm
Common Application Scenarios
808 semiconductor hair removal devices, 810 multi - function beauty instruments, White Swan 810 rejuvenation devices, German 810 rejuvenation devices, Soprano beauty instruments, 810 multi - function all - in - one machines, etc.
The 808 laser power supply makes beauty more precise, safer, and more long - lasting!
It helps medical aesthetics equipment achieve a high - performance leap!
With ultimate - stability medical - grade standards, it makes every piece of equipment an efficient and precise "treatment expert"!


Оставляйте свои сообщения
x
x

Отправлено успешно

Мы свяжемся с вами как можно скорее